GET Control Panel
Touch Screen - SCADA system
Control panel for GETPack automation is provided with Start-Delta or Soft Start or Inverter starting system according to customer needs: The control box can be provided from IP21 up to IP55 and is suitable to be installed in safe area.
GETPack control panel has two main sections:
A) Section for automatic control and monitoring module.
B) Electric power distribution section.
The control panel has automatic compressor start-up/stop upon minimum/maximum pressure in the storage reached with manual override.
Safety features include Gas analyzer for continuous detection of the gas concentration in the module. Provides an indication of the measurement and has auto shutdown functions for high concentrationof gas. It executes the self-diagnosis of the sensor and reading devices signalling any malfunctions.
Automatic compressor monitoring minimum crank gear oil pressure, minimum/maximum inlet gas pressure, maximum gas temperature at the discharge of each stage will trigger shut-down with emergency override.
Note: A connection is provided for a remote emergency push button for customer’s use.
Optional: intestage pressure, Profibus communication port.
Dimensions: 2000 x 1400 x 600mm
ALSO SEE


Automatic compressor control with auto fault monitoring